Cold feed screw extruder

Cold feed screw extruder

120ColdfeedscrewextruderTechnicalparameter1.Applicableproductsize:rubberhosewithaminimumspecificationofφ13mm(innerdiameter)andamaximumspecificationofφ76mm(innerdiameter).2.Φ120*16DPinColdFeedExtrud...

DESCRIPTION

    120 Cold feed screw extruder

    Technical parameter

    1.Applicable product size: rubber hose with a minimum specification of φ13mm (inner diameter) and a maximum specification of φ76mm (inner diameter).

    2.Φ120*16D Pin Cold Feed Extruder

    Screw diameter: 120mm

    Screw aspect ratio L/D: 1:16

    Screw speed rmp: 43rmp

    Center height: 2500px

    Screw material: 38CrMoAIA

    Screw working surface treatment: the hardness of the desalination layer HV900, the depth of the desalination layer 0.5mm

    Barrel working surface treatment: alloy layer hardness HEC62, alloy layer degree 1.5-2mm

    Feeding section bushing material: 38CrMoAIA

    Feeding section bushing face treatment: desalination layer hardness HV900, desalination layer depth

    0.5mm

    Drive motor power (Kw): DC110

    Gearbox: with hard tooth surface, gear material is carburized, quenched and ground with high-quality low-carbon alloy. The gear pair transmission accuracy is grade 6. Under full load, the gear noise is less than 85db. The gears and bearings in the reduction box are lubricated with thin oil, and there is a lubricating oil cooling device.

    Maximum glue discharge (inorganic head): 750kg/h, because the glue discharge is related to the formula of the product, a 15% error is allowed.

    3.Machine head

    Maximum working pressure (Mpa): 45

    Head drive mode: manual

    Head pressure sensor: domestic

    Head temperature sensor: domestic

    4.Temperature control device

    The total number of temperature control units in the whole machine: 4 units

    Extruder temperature control unit: screw, plasticizing stage I, plasticizing stage II, extrusion section

    Head temperature control unit: 1 unit

    Temperature adjustment range: 45-95

    Control accuracy: ±1.5

    Temperature control principle: closed-circuit circulation, heat exchange water for cooling or heating, and softened water for internal circulation